Comparative Evaluation of LSTM, BiLSTM, and a Hybrid CNN-BiLSTM-Attention Model for Short-Term and Day-Ahead Electricity Load Forecasting

Authors

  • Sadeeq Ullah Department of Computer Science, Bacha Khan University Charsadda Author
  • Asad Ullah Department of Computer Science, Bacha Khan University Charsadda Author
  • Atta Ur Rahman Lecturer, Department of Computer Science, Bacha Khan University Charsadda Author
  • Naeem Jan Lecturer, Department of Computer Science, Bacha Khan University Charsadda Author
  • Muhammad Shahid Lecturer, ICS/IT, The University of Agriculture, Peshawar Author

DOI:

https://doi.org/10.66021/

Keywords:

Electricity Load Forecasting, Long Short-Term Memory, Bidirectional Lstm, Convolutional Neural Network, Attention Mechanism, Time Series Forecasting, Deep Learning

Abstract

Reliable electricity load forecasting is essential for grid stability, generation scheduling, and demand-supply balancing, particularly in regions such as Pakistan that face chronic supply shortfalls. Building on a base study that compared Long Short-Term Memory (LSTM) and Bidirectional LSTM (Bi-LSTM) models against ARIMA and SARIMA on a univariate prosumer dataset, this paper extends the comparison in three directions: it evaluates a proposed Hybrid CNN-BiLSTM-Attention architecture alongside the LSTM and Bi-LSTM baselines, it replaces the single date time feature of the base study with a fifteen-column multivariate feature set (cyclical calendar encodings, lag features at 1, 24, and 168 hours, and 24-hour rolling statistics), and it evaluates every architecture at both a 1-hour-ahead and a 24-hour-ahead forecasting horizon rather than one-step-ahead alone. All three models were trained and tested under identical conditions on the public PJM East (PJME_MW) hourly electricity load series (145,224 usable hourly records, January 2002 to August 2018) using a 168-hour lookback window, an 80/10/10 chronological train/validation/test split, the Adam optimizer, and early stopping. On the held-out test set, Bi-LSTM produced the lowest error for 1-hour-ahead forecasting (RMSE = 528.17 MW, MAE = 402.62 MW), while LSTM was marginally the most accurate model for 24-hour-ahead forecasting (RMSE = 2014.78 MW, MAE = 1475.48 MW), narrowly ahead of Bi-LSTM (RMSE = 2033.93 MW). The Hybrid CNN-BiLSTM-Attention model recorded the highest absolute error at both horizons (RMSE = 2658.79 MW at h = 1; RMSE = 2467.19 MW at h = 24), but its error changed by only -7.2% between the two horizons, compared with +103.4% for LSTM and +285.1% for Bi-LSTM, indicating markedly better cross-horizon stability. Attention-weight analysis showed the hybrid model consistently assigning the largest weight to the most recent hour and a secondary peak at the 168-hour (one-week) lag, giving a transparent, interpretable account of which historical hours’ drive each forecast. The results suggest that, under the tested configuration, richly engineered multivariate features contribute more to forecasting accuracy than additional architectural complexity, while attention-based hybrid models trade some absolute accuracy for stability and interpretability across forecast horizons.

 

 

Downloads

Download data is not yet available.

Downloads

Published

2025-01-30

How to Cite

Comparative Evaluation of LSTM, BiLSTM, and a Hybrid CNN-BiLSTM-Attention Model for Short-Term and Day-Ahead Electricity Load Forecasting. (2025). Annual Methodological Archive Research Review, 3(1), 26-43. https://doi.org/10.66021/

Similar Articles

1-10 of 1128

You may also start an advanced similarity search for this article.

Most read articles by the same author(s)